Skintact Easibeat Multi-Function Philips Heartstart Defibrillator Electrodes: # DF27

Product Description:

SKINTACT Easibeat Multi-function Defibrillation Electrodes are designed for the use of external defibrillation, non-invasive pacing, synchronized cardioversion, and monitoring on adults and children over 8 years weighing more than 25 kg (55 lbs.).  Our unique C-line technology guarantees perfect processing of all materials according to ISO 13485 and at the same time reduces cost.

Excellent Skin Coupling: Proper adhesion between electrodes and skin ensures firm contact to all skin types and is gentle to the patient’s skin: Optimal water absorption of gel, good adhesion on perspiring skin, utilization of minimal thickness layers of materials increases flexibility, maximum contact area means minimum impedance values and in addition reduces thermical and mechanical exposure of the skin.  Overlapping Gel:  This unique technology minimizes the risk of burns because of: elimination of tin edge exposure, better current distribution, no flashover, and minimized edge effect.

Multi-function: continuity of patient care eliminates replacing the electrodes between developing stages of the patient’s treatment.  Quality Assurance: Each set is subject to a 100% test and inspection before packaging.  Clearly Printed Instructions:  Instructions are clearly printed in two colors (green, black) on the electrodes for correct placement.  Quick’n’Easy:  Extended Liner designed specifically for quick and easy application and removal.  See tab for more information.

To view additional Defibrillator Chart Paper & Accessories, click the following link to browse our Defibrillator Accessories Catalog.

  •  Philips Heartstart
  • Connector (compatible): Heartstart FR2, Heartstart FR2(+), Heartstream Forerunner, Heartstart MRx, Heartstart XL
  • For the use of external defibrillation
  • Non-invasive pacing, synchronized cardioversion, and monitoring on adults and children over 8 years weighing more than 55 lbs
  • Perfect processing of all materials according to ISO 13485
  • Reduces cost
  • The highest degree of skin contact, minimal impedance and is gentle to the patient’s skin
  • Firm contact to all skin types: including perspiring skin
  • Unique technology minimizes the risk of burns, elimination tin edge exposure, better current distribution, no flash-over, and minimized edge effect
  • Multifunction: eliminates replacing the electrodes between developing stages of the patient’s treatment
  • Instructions are clearly printed in two colors (green, black) on the electrodes for correct placement
  • Extended Liner designed specifically for quick and easy application and removal
  • Packaging Standard: 1 pair/pouch, 10 pouches/box, 60 pouches/case
  • Shelf Life: 36 months
  • Latex Free